HISCL-800

Add to wishlist
Category:

HISCL-800 is the latest addition to HISCL family of automated immunoassay systems. A fast, reliable and robust system with a small footprint catering to small and medium-size laboratories.

HISCL-800

The unique features of HISCL-800 include fast reaction time with throughput of up to 100 tests per hour, delivering highly sensitive and specific clinical results with small footprint, making it an ideal partner for small and medium-sized laboratories.

  • Rapid analysis – 17 mins for all assays
  • Highly sensitive and specific – by incorporation of the brilliant CDP-STAR chemiluminescent substrate and adoption of bound-and-free (B/F) wash separation
  • Low sample volume – Only 10 to 30 µL sample is required, allows accurate testing while conserving precious sample
  • STAT position – For immediate access to emergency testing
  • Wide measurement range – Reduction in repeat testing and sample dilution
  • High usability – Capacity for 24 assays, RFID Technology
  • Carryover Prevention – With single use pipette tips and membrane filterfor minimised carryover contamination
  • Sysmex Network Communication System (SNCS) – for online QC and online customer support

*The HISCL-800 are only available in Philippines, Malaysia, Indonesia, Vietnam, Thailand and India.

For more product information, please contact your local Sysmex agent.

Measurement Principle Chemiluminescence Enzyme Immunoassay (CLEIA)
Number of Parameters Onboard- Up to 24 Parameters
Processing Capacity 100 tests per hour
Reaction Time Approximately 17 minutes (time from sample aspiration to measurement result display)
Number of Samples Set Up Up to 30 samples loading capacity
Number of STAT Positions 1 sample
Required Specimen Volume 10 – 30µL
Sample Container Test tube (open)
Diameter (outer diameter): 13 – 16mm
Height: 75 – 100mm
Dead Volume The depth of the serum or plasma component from the surface of liquid is 5mm or more
Sample Cup 4 mL conical cup
Dead volume 0.15mL
Reagent Management Function – R1, R2, R3 reagents, Luminescence substrate set RFIDline washer, cleaning fluid, probe washer: barcode
Data Storage 100,000 sample results (maximum)
Precision Management L-J (Chart) or X-bar (Chart)
External Output RS232C, LAN
Power Specifications – Analyser AC 100 – 240 V AC
Pneumatic Units 220 V AC
Rated Frequency 50 Hz/60 Hz
Printing System External printer
Accessory Handheld barcode reader
Options Drainage tank, indicator light
Main Unit
  • Dimensions (W x D x H) Approx. 1,018 x 1089 x 1,295 mm (including thesampler)
  • Weight Approx. 320 kg
Compressor
  • Dimensions (W x D x H) Approx. 280 x 355 x 400 mm
  • Weight Approx. 17 kg
+ Features & Benefits
  • Rapid analysis – 17 mins for all assays
  • Highly sensitive and specific – by incorporation of the brilliant CDP-STAR chemiluminescent substrate and adoption of bound-and-free (B/F) wash separation
  • Low sample volume – Only 10 to 30 µL sample is required, allows accurate testing while conserving precious sample
  • STAT position – For immediate access to emergency testing
  • Wide measurement range – Reduction in repeat testing and sample dilution
  • High usability – Capacity for 24 assays, RFID Technology
  • Carryover Prevention – With single use pipette tips and membrane filterfor minimised carryover contamination
  • Sysmex Network Communication System (SNCS) – for online QC and online customer support

*The HISCL-800 are only available in Philippines, Malaysia, Indonesia, Vietnam, Thailand and India.

For more product information, please contact your local Sysmex agent.

+ Specifications
Measurement Principle Chemiluminescence Enzyme Immunoassay (CLEIA)
Number of Parameters Onboard- Up to 24 Parameters
Processing Capacity 100 tests per hour
Reaction Time Approximately 17 minutes (time from sample aspiration to measurement result display)
Number of Samples Set Up Up to 30 samples loading capacity
Number of STAT Positions 1 sample
Required Specimen Volume 10 – 30µL
Sample Container Test tube (open)
Diameter (outer diameter): 13 – 16mm
Height: 75 – 100mm
Dead Volume The depth of the serum or plasma component from the surface of liquid is 5mm or more
Sample Cup 4 mL conical cup
Dead volume 0.15mL
Reagent Management Function – R1, R2, R3 reagents, Luminescence substrate set RFIDline washer, cleaning fluid, probe washer: barcode
Data Storage 100,000 sample results (maximum)
Precision Management L-J (Chart) or X-bar (Chart)
External Output RS232C, LAN
Power Specifications – Analyser AC 100 – 240 V AC
Pneumatic Units 220 V AC
Rated Frequency 50 Hz/60 Hz
Printing System External printer
Accessory Handheld barcode reader
Options Drainage tank, indicator light
Main Unit
  • Dimensions (W x D x H) Approx. 1,018 x 1089 x 1,295 mm (including thesampler)
  • Weight Approx. 320 kg
Compressor
  • Dimensions (W x D x H) Approx. 280 x 355 x 400 mm
  • Weight Approx. 17 kg
+ Documents